New Clients
Bartlett Bay Consulting has recently been selected to
assist in the measurement, analysis, and certification of new
products at Rudolph Technologies of Flanders, New Jersey.
(Back
to Top)
___________________________
Notes of Interest
Steve Silverman, President of Bartlett Bay
Consulting will be leading the ITRS Surface Preparation Focus
Team on Backside Particles. This committee is charged with
updating the "Backside Particle" section of the 2004 ITRS
Roadmap.
If you are interested in being a participant
in this committee, please contact Steve (contact information
at bottom of newsletter)
(Back
to Top)
___________________________
Travel Schedule
Listed below is our travel schedule for near
future. If you would like to confirm a date for us to stop by
while in your area, please call and we’ll make sure to include
a visit to discuss how our services can help your firm. In
addition, we would be glad to schedule a special presentation
to your staff or other user group interested in learning more
about Bartlett Bay Consulting & Contamination Control.
|
· Metropolitan
Boston |
- Periodically from October through
December, 2003. |
| · Flanders, NJ |
- October 30-31, 2003 |
(Back
to Top)
___________________________
Q & A
I welcome your feedback & questions! In each issue, I
will be answering questions that I receive from you. If you
have any questions you wish to submit, please visit http://www.bartlettbayconsulting.com/
and use the form provided there.
October's Question:
"Contamination control involves
particles in the air as well as on wafers. Is there any
direct relationship of the quantity of these particles and
the number of defects in the Silicon and failures of the
chip?"
A very difficult question, and there is no simple answer.
The short (very short!) answer is "Yes". There have been
exhaustive studies on these relationships which have led to
complicated algorithms which give semiconductor and process
engineers an idea of how many particles affect yield.
The entire ITRS roadmap is based on these algorithms. If
you are really interested in finding out more about these
relationships, I urge you to get involved in an ITRS, SEMI or IEST
committee.
(Back
to Top)
____________________________
Feature
Article:
Measuring Particles on Wafers, Part 3:
Back FOR the future
In our April issue, we explored the problems and
intricacies of measuring particles on the
frontside (top) of wafers as a criteria for
benchmarking contamination levels inside wafer-handling
environments (minienvironments, etc). We saw that the
specifications on this test were hard to achieve but that a
well-designed minienvironment could meet these requirements.
In this issue, we look at particles added to the
backside (bottom) of the wafers, and you will
discover that these adders give an entirely different
perspective regarding cleanliness. Furthermore, since the
issue of backside particles is so much harder to both
understand and measure than frontside particles, this will be
a two-part report, with the second part in the next
issue.
Before looking closely at the difference between frontside
and backside particle adders, we have to address the question
of “Why do backside particles matter?”. After all, it is clear
that particles on the top of the wafers can directly result in
defects on the surface where pattern sensitive lithographic
and doping processes occur: it is fairly obvious that a
particle on this surface could make a transistor or a chip
non-functional. As there are no active devices on the backside
(yet!... we may have to visit this issue at some point!),
there are two theories as to how particles on the backside
could affect the frontside processes:
1) particles on the backside of the
wafer could “fall” down onto the wafer(s) beneath. I don’t
consider this a viable theory as extensive front side PWP
(“Particles per Wafer per Pass”) testing has not shown any
evidence of this.
2)
particles on the backside could distort the silicon
lattice and result in a frontside defect; the size of the
offending particles and the actual defect level is not well
understood, but it is a valid concern.
If we assume that backside particles are problematic, and
most fabs now do, then we have to look at the mechanism of how
they get on onto the wafer. Again, a comparison to frontside
particle adders is helpful here.
First consider what we know about frontside particle
adders: they virtually all result from airborne particles
inside the handling areas; there are many sources, but the
main thing to remember is that the particles in the
environment have to somehow move to the surface of the wafer
(which is, for the most part, held horizontally) through the
air and then stick to the wafer; however, in a minienvironment
which has well designed airflow, the clean air from the
filters works to prevent the movement of the particles to the
wafer surface. There are many factors in a well-designed
minienvironment, but good airflow design is key to keep
particle adders low.
Not so for backside particles...
Backside Particle
Adders
Backside particle adders are a result of a completely
different mechanism:
If we assume that airborne particles won’t land/stick
on the backside of wafer (yes, there is the issue of
electrostatic attraction, and I will discuss that in the
next issue of this newsletter), then all the particles which
are found on the backside of the wafer must be due to
contact of the handling robot (“Paddles” or “End
Effectors”). Simply stated, the more contact times, the more
particles.
There-in lies the rub! All this high-tech work which we
contamination control experts have devoted to keeping
particles off the frontside of wafers through our use of
clever methods of airflow handling does little or
nothing for the backside, where the cleanliness
of the environment plays a secondary role, at best. This is
very evident in the particle counts: the PWP specifications
for the number frontside particles >0.2um (a good benchmark
size for backside particles) in a state of the art
minienvironment is in the order of <1 (!); the number of
particles added to the backside during a single touch in the
minienvironment is in the order of 100s-1000s (!!); it is very
evident that these particles are NOT coming from the
environment. Unfortunately, we don’t know much more than
that!
(Lack of) Knowlege-Base
The list of what we don’t know about the whole issue of
backside particles far exceeds what we do know. Much of this
is because the problem is a new one, and there have been very
few studies to define the techniques/protocols for
measurements; take, for example, the fundamental issue of the
physics of the transfer mechanism itself: if we knew how the
particles are transferred to the wafer, we might have a better
idea how to prevent the transfer. The whole issue of backside
particles is, in fact in utter confusion by the industry; even
the much respected ITRS (International Roadmap for
Semiconductors), on which we base literally all of the
semiconductor industry specifications, is having problems with
the specification. An excerpt from the 2003 update (found in
the footnotes for tables 50a and 50b):
“Metrics for critical back surface particle size and
back surface particle count are not being listed in 2003.
While it is recognized that back surface particles are
important to control and are assessed during equipment
qualification, there is no clear empirical or theoretical
model which links back surface particles to device yield.
... It is not possible to measure absolute levels of back
surface particles on in-process wafers due to large
variations in back surface finish and films. A generally
accepted practice is to process wafers with the polished
front surface down in order to assess back surface particle
adders for a particular process or operation. Current best
practice indicates that back surface particle adders for any
particular process step* in 2003 should be less than 400 at
0.2 micron.”
*process step here refers to a single touch by the
robot end-effector
Here is what we do know:
When an End Effector touches a wafer, the exact paddle
imprint is seen on the wafer (using a wafer scanning tool
such as the KLA-Tencor SP1); looking like a fingerprint,
particles from the paddle are transferred directly to the
backside of the wafer. We know that (surprise, surprise) the
fewer contact surfaces the lower the particle counts, and it
would appear that the easiest way to meet the an industry
spec (if there was one, and at sometime soon, there surely
will be as many OEMS and Fabs are coming out with their own)
would be to do one of the following:
a. Touch the backside with a minimum
contact area or b. Not touch the
backside of the wafer (used edge grip technology)
or c. Find a material that
doesn’t transfer the particles or is particle
free
Let’s take them in order:
a. Touching the wafer with a minimum
contact area is problematic from a point of view of
throughput: Whether or not a paddle uses vacuum or the
contact surface to hold the wafers during transfer, the
paddle must be designed such that it can transport the wafer
rapidly between process stations; limiting the contact area
rapidly degrades this ability; however, with the right
compromise between the right materials and contact are, this
solution may work, but as specifications get tighter, it
probably is not an workable long-term solution.
b. Edge grip technology is the most
viable long term solution to the problem of backside
contact/contamination; it, however, hasn’t yet been
thoroughly proven, and it has real and potential
liabilities, three of which are:
- Extra width of the end-effector (will not work with
certain minienvironment configurations)
- Possible particle generation (due to holding the thin
edge of the wafer)
- Wafer stresses, etc.
c. Finding material(s) that doesn’t add
particles to the backside is the holy grail of the industry,
and has the obvious concerns including cost (the biggie!),
holding power (the throughput problem), long-term
wear/reliability, etc.
If you are still with me, dear reader, then you are
probably as confused as everyone else regarding where we are
and where we are going in the issue of backside particle
problems, specifications, measurements, and protocols.
Next month we will look into how we actually measure the
particles, and that will give us some insight as to how we
might be able to solve the problem.
__________________________
BBC
Challenge!
There is no homework problem in this issue
(though credit will still be given for submission of answers
to the question posed in the April edition), but instead there
is a contest. The first
person who comes up with the correct answer to the question
posed below will receive up to one-hour (one phone
call) of Bartlett Bay Consulting time to discuss backside
particle issues AT NO CHARGE. A
priceless offer.
Here’s the situation: Removing small particles
from surfaces has always been problematic, especially for
those particles <0.2um (said to be due to van der Waals
force)... and yet, engineers have found a method that
actually cleans up the robotic End-Effectors.
Yes!
Using this method has actually reduced particle counts on
these surfaces. The method isn’t perfect, but it has shown
to reduce particle counts by about an order of magnitude or
more. Impressive! How? Who knows! (remember the physics
of this problem is not at all understood).
Here’s the question:
What is this
“high-tech” method”? (Hint: the answer is
buried in the text of this
newsletter)
_______________
Sources of Specification Information:
· ITRS -
International Technology Roadmap for
Semiconductors · SEMI -
Semiconductor Equipment and Materials International ·
BBC
- Bartlett Bay Consulting. See Contact
Information below.
(Back
to Top)
_____________________________
|